OFF-GRID | INVERELL, NSW
APPLICATION
-
1 phase residential 10KVA Hybrid with storage
COMMISSIONED
November 2020
SYSTEM OBJECTIVE
Our client, a farmer in Inverell, New South Wales, had an old 10KW solar system without battery storage. He wanted it replaced with a new system that could also function as a stand alone system indefinitely for their house loads. Having a long overhead lead into the property (a couple km), there was a high chance of black out from blowing branches in storm season - our client wanted resilience for this reason.
USEABLE BATTERY STORAGE
20KWh @ up to 100% DOD with the possibility of an extra battery next year bringing the total to 30Kwh.
INSTALLED PV
-
40 x 315W Seraphim blade
SYSTEM COMPONENTS
-
2 x Victron Multiplus 2 5KVA
-
2 x Victron smart solar charger 250/100
-
2 x 10KWh Z-Cell flow batteries
ADDITIONAL NOTES
A Victron energy meter was installed so the 2 sheds on the property can also benefit from the solar and batteries while the grid is still connected.